BRQRX - PS-12400 RECHARGEABLE BATTERIES

  • MSDS: BRQRX
  • Manufacturer: POWER SONIC CORP
  • Product Name: PS-12400 RECHARGEABLE BATTERIES
  • National Stock Number: 6140-01-160-6586
Product Identification

Product ID:PS-12400 RECHARGEABLE BATTERIES
MSDS Date:01/14/1990
FSC:6140
NIIN:01-160-6586
MSDS Number: BRQRX

Responsible Party
POWER-SONIC CORP
3106 SPRING ST
REDWOOD CITY, CA 94063-3929
US

Emergency Phone: 415-364-5001

Info Phone: 415-364-5001

Cage: 56309

Contractor
POWER-SONIC CORP
5242 REDWOOD CITY, CA 94063-3929 US

Telephone: 650-364-5001

Cage: 56309

Ingredients

NO INGREDIENT FOR THIS FORMULATION_INGREDIENT

Hazards

LD50 LC50 Mixture:LD50 (ORAL RAT) IS 2140 MG/KG (H2SO4)
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SULFURIC ACID MAY CAUSE IRRITATION TO
THE EYES, NOSE AND THROAT. DIFFICULTY IN BREATHING MAY BE
EXPERIENCED. ACID SPLASHED IN EYES OR ON SKIN MAY CAUSE BURNS OR
IRRITATION. REPEATED OR PROLONGED EXPOS URE TO MIST OR VAPORS OF
SULFURIC ACID MAY CAUSE EROSION OF THE TEETH.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:INHALATION: CAN CAUSE BURNS OF THE UPPER
RESPIRATORY TRACT AND LUNGS. SKIN CONTACT MAY CAUSE BURNS OR
LOCALIZED IRRITATION. EYE CONTACT: MAY CAUSE IRRITATION, CORNEAL
BURNS AND CONJUCTIVITIS. BLINDNES S MAY RESULT OR SEVERE OR
PERMANENT INJURY. INGESTION: ELECTROLYTE MAY CAUSE BURNS TO THE
MOUTH, ESOPHAGUS AND STOMACH.
Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF AILMENTS
OR WITH A PRE-EXISTING DISEASE INVOLVING THE RESPIRATORY TRACT OR
TEETH MAY BE AT INCREASED RISK FROM EXPOSURE.

First Aid

First Aid:INHALATION:REMOVE TO FRESH AIR. RESUSCITATE IF NOT BREATHING.
GET MEDICAL ATTENTION. EYES:IMMEDIATELY FLUSH WITH PLENTY OF WATER
FOR 15 MINUTES HOLDING EYELIDS OPEN. GET PROMPT MEDICAL ATTENTION.
SKIN :REMOVE CONTAMINATED CLOTHING. WASH WITH PLENTY OF WATER FOR
15 MINUTES. GET MEDICAL ADVICE. INGESTION:DO NOT INDUCE VOMITING.
GIVE NOTHING BY MOUTH IF UNCONSCIOUS. GET IMMEDIATE MEDICAL
ATTENTION.

Fire Fighting

Flash Point:NONE
Extinguishing Media:USE DRY CHEMICAL, FOAM, WATER SPRAY.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:KEEP AWAY FROM OPEN FLAMES AND SPARKS.
INPROPER CHARGING AND IGNITION OF RESULTING GASES CAN CAUSE
EXPLOSION, PARTICULARLY IN GAS TIGHT ENCLOSURES.

Accidental Release

Spill Release Procedures:SHOULD A BATTERY BREAK OPEN, ISOLATE AREA.
ELECTROLYTE SHOULD BE ABSORBED WITH A NON-ORGANIC TYPE ABSORBENT
SUCH AS DRY SAND OR EARTH. AVOID DILUTION WITH WATER. LEAD SPILLED
FROM THE BATTERY SHOULD B E VACUUMED, DO NOT SWEEP OR USE
COMPRESSED AIR.
Neutralizing Agent:USE SODA ASH OR BAKING SODA TO NEUTRALIZE THE
ELECTROLYTE.

Handling

Handling and Storage Precautions:AVOID THE USE OF UNINSULATED TOOLS. IF
THEY ARE REQUIRED, TAKE CARE NOT TO ELECTRICALLY SHORT THE
TERMINALS. REMOVE METAL JEWELRY BEFORE SERVICING.
Other Precautions:UNDER NORMAL CONDITIONS OF USE, EXPOSURE TO LEAD OR
LEAD CONTAINING COMPOUNDS DOES NOT OCCUR. SHOULD A BATTERY BREAK
OPEN AND A LEAD SPILL OCCUR, PRECAUTIONS SHOULD BE TAKEN TO PREVENT
LEAD DUST FROM BECOMING AIR BORNE.

Exposure Controls

Respiratory Protection:UNDER NORMAL CONDITIONS OF USE, RESPIRATORY
PROTECTION IS NOT REQUIRED. HOWEVER, IF CONDITIONS ARISE THAT
REQUIRE THEIR USE, USE ONLY NIOSH/MSHA RESPIRATORS. USE IN
ACCORDANCE WITH 29 CFR 1910.134.
Ventilation:BATTERY CHARGING AREAS MUST BE ADEQUATELY VENTILATED TO
PREVENT HAZARDOUS CONCENTRATIONS OF FLAMMABLE GAS OR ACID MIST.
Protective Gloves:PVC, NEOPRENE
Eye Protection:CHEMICAL SPLASH GOGGLES AND FACE SHIELD
Other Protective Equipment:EYE WASH STATION AND SAFETY SHOWER.
INDUSTRIAL-TYPE IMPERVIOUS WORK CLOTHING, BOOTS AND APRON AS
REQUIRED.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
IF THE BATTERY ROOM IS AIR CONDITIONED AS PART OF AN OVERALL BUILDING
SYSTEM, THE EXHAUST AIR FROM THE BATTERY ROOM SHOULD NOT BE
RETURNED TO THE AIR DISTRIBUTION SYSTEM. THE ROOM SHOULD HAVE ITS
OWN EXHAUST SYSTEM CONNECTED DIRECTLY TO OUTSIDE AIR. HYDROGEN GAS
IS LIGHTER THAN AIR AND DIFFICULT TO DETECT.

Chemical Properties

HCC:C1
Appearance and Odor:RECTANGULAR/SQUARE IN SHAPE-ORANGE IN COLOR-NO ODOR

Stability

Stability Indicator/Materials to Avoid:YES
SOLVENTS MAY DISSOLVE CASE MATERIAL.
Hazardous Decomposition Products:SEVERE OVERCHARGING AND OVERHEATING
MAY CAUSE HYDROGEN, OXYGEN AND SULFUR OXIDE FUMES.

Disposal

Waste Disposal Methods:BOTH ELECTROLYTE AND SCRAP BATTERIES ARE
REGULATED HAZARDOUS WASTE. SCRAP BATTERIES CONTAIN MATERIALS WHICH
ARE RECYCLABLE AND MUST BE RETURNED TO AUTHORIZED RECYCLER.
ELECTROLYTE SHOULD BE HAULED TO A PERMITTED TREATMENT FACILITY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.